Pool builders in Goodland work in a village wrapped in water
Goodland sits on the southeast side of Marco Island, about 6 miles east of the city of Marco Island, and it's unincorporated. It's the closest community to Cape Romano, where Hurricane Wilma made its official Florida landfall. In the 2020 census, 312 residents lived in 98 households. In 2010 it was 267.
The whole place is 0.35 square miles, and 57.47 percent of that is water. Goodland Bay and Blue Hill Creek nearly wrap around it. The village has several seafood restaurants and charter boat operators. Your backyard is a small piece of land with water close on every side, so we measure twice before anyone sketches a shape.
Before we draw a line, we look at how a delivery truck and a concrete pump get into the yard, because access can decide the order of the whole job. Bring your survey to the walk-through and we'll mark the setbacks and the equipment pad on it together.
Collier County, not Marco Island, reads your plans
Collier County Growth Management handles Goodland, not the city of Marco Island's Building Services desk. Collier's in-ground pool requirements call for engineered structural detail, a dimensioned design plan, site-specific TDH calculations, the pump make and model with its pump curve, the lighting choice, the deck material and a Residential Swimming Pool Safety Act form naming your barrier method.
Once a job adds more than 400 square feet of impervious area, a Florida surveyor and mapper, architect or engineer has to certify, sign and seal the site plan, and it can't be more than 6 months old. On a septic lot, the plan has to show the distance to the system, at least 5 feet. Collier may also want a Storm Water Plan. Tell us at the visit whether it's septic or sewer. Florida law (F.S. 713.13) also requires a recorded Notice of Commencement with the Clerk of the Circuit Court before work starts on any improvement over $2,500.
We build that package and file it for you. The Marco Island page shows how the city's own desk runs things, and the permits guide lines Collier up next to Lee County.
What an 11 foot flood elevation does to the deck and the equipment
At one sample point in Goodland, FEMA's flood layer returned zone AE, a coastal floodplain, with a static base flood elevation of 11 feet. That's one dot on a map. It isn't your parcel. Enter your own address on FEMA's flood map, then ask Collier's floodplain office for your zone and elevation. The office publishes elevation certificate and building-standard guidance for homeowners.
Your elevation gets used, since the equipment pad and the deck are checked against it. Collier's portal asks if the declared value of the work is more than 25 percent of the structure's improved value, and its floodplain forms test FEMA's 50 percent rule any time the scope improves a structure. The county's exemption letter for work under $7,500 does not reach a flood hazard area. A small job here doesn't get that shortcut.
Draw the pad, the deck and any cage on one sheet, with your elevation certificate next to it. Pool builders in Goodland should write the elevation work into the estimate as its own line, and we do.
Bay-side, and a soil label that says little about the water
Goodland is on the bay side. The state's coastal construction control line only reaches work seaward of that line (rule 62B-34.160 covers Collier). So the one question left for the FDEP coastal program is whether your parcel falls seaward. We can't tell from the street. If it does, F.S. 161.053 puts resurfacing and minor repairs on the general-permit list. That route needs notice at least 30 days before work starts.
The soil map calls the sample point Urban land-Aquents complex, organic substratum. That label says nothing about how deep the water sits under your yard. The water table on the lot sets the dewatering plan and the hydrostatic relief device, which the building code requires wherever a water table is anticipated. With the bay this close, both go into the estimate from the start, because hoping for a dry week isn't a plan.
Bring what both offices tell you to the visit. We'll mark it on your survey, and the design only gets drawn once.
Cage permits and wind on a Goodland lot
Pool builders in Goodland file the cage on its own, because in Collier a screen enclosure has its own Aluminum Structure permit (PRAS). When the pool is permitted separately, its certified site plan can be reused. The county wants a final spot survey too, with a note naming the screen-enclosed area. Collier gives 150 mph as the minimum design wind speed for a Category II structure, and up to 170 mph in some regions on its wind zone map. Find out which speed applies at your address before you pick a frame.
The building code wants extruded aluminum members with an actual wall of at least 0.040 inch. Vinyl, glass and acrylic panels have to be removable, with a decal saying to take them out above 75 mph. A cage built to code can double as your barrier. A new cage typically runs $9 to $16 per sq ft. A rescreen runs $3 to $6 per sq ft. A typical cage job lands at $15,000 to $35,000. The screen enclosure page and the hurricane code guide cover frames and panels.
What a Goodland build, remodel or resurface typically runs
In our range, a custom gunite pool runs $65,000 to $150,000+. A typical 15x30 to 20x40 with a standard deck lands at $75,000 to $120,000. Luxury work runs $150,000 to $350,000+. A remodel with new tile, coping, finish and equipment is $18,000 to $50,000. Resurfacing is $6,000 to $16,000. Adding a spa to an existing pool is $12,000 to $28,000. These are typical ranges, not a quote. The free written estimate comes after we see the yard.
Three things move the number on this ground: dewatering with the relief device, the elevation work an AE zone asks for, and how the trucks and the pump get in. Paver decks are $8 to $14 per sq ft and travertine is $14 to $30 per sq ft. The new construction page, the renovation page and the resurfacing page break each job down. The cost guide explains what moves the price. Every one of those lines shows up on its own in the written estimate.
Hire pool builders in Goodland who read the flood map first
Searching for pool builders in Goodland, or a swimming pool contractor near Marco Island? Here's the plain version. Call (239) 899-6371 and we'll walk the yard, check your survey against Collier's list, and write up every line before any work begins. The visit and the estimate cost nothing, and we pull the pool permit.
We also work in Marco Island, Isles of Capri, Naples Manor, Lely Resort and Verona Walk. Each has its own page, because the lots, the flood maps and the plan reviewers differ town by town.
Bring these to the first visit: your survey, any elevation certificate, a photo of the yard with the water side marked, a note on septic or sewer, and a rough wish list for the pool, spa, deck and cage. With those in hand we can mark the pad, the deck edge and the cage line on the survey while we're standing in the yard. The written estimate follows without a second trip.
Sources
- Pool (PRSPL) application requirements, Collier County Growth Management
- Aluminum Structures (PRAS) application requirements, Collier County Growth Management
- Goodland, Florida, Wikipedia
- National Flood Hazard Layer, FEMA
- Coastal Construction Control Line Program, Florida Department of Environmental Protection
- F.S. 161.053 Coastal construction and excavation, Florida Legislature
- Fla. Admin. Code R. 62B-34.160, Florida Department of Environmental Protection (Cornell LII copy)
- 2023 FBC-Residential, Section R4501, UpCodes / ICC Florida Building Code
- 2023 FBC-Building, Chapter 20 Aluminum, UpCodes / ICC Florida Building Code
- Residential swimming pool safety act, Chapter 515, Florida Legislature