Pool permits in Naples, Collier County and Lee County: whose desk is yours?
Your Naples mailing address might sit under any of several building desks. Inside city limits, the City of Naples reviews the yard. Growth Management takes unincorporated Collier County. Marco Island has its own Building Services, and Everglades City passes its reviews to county staff under an interlocal agreement.
North of Collier the map breaks up again. Unincorporated Lee County files through eConnect. Bonita Springs, Estero, Fort Myers and Cape Coral each keep their own offices, and Charlotte County and Punta Gorda sit further up the coast.
Send us the address and we name the desk before we talk price. That answer sets your forms, your fees and your inspection list. Naples Swimming Pool Construction Co files the paperwork as part of new pool construction, and the free written estimate says what the filing covers.
What the posted pool checklists share
The posted pool checklists from Collier, Lee, the City of Naples, Fort Myers, Cape Coral and Charlotte all start in the same place: a site plan or survey and engineered drawings of the shell. From there they split. Collier, Lee, Cape Coral and Charlotte also want hydraulic or TDH numbers showing how the pump and piping move the water.
Collier wants the pump make, model and horsepower with the manufacturer's curve, plus TDH calculations. Lee asks for signed and sealed engineered plans with hydraulic calculations. Cape Coral wants hydraulic flow velocity calculations and the pump curve, and Fort Myers wants a note that the plans meet the 8th Edition (2023) Florida Building Code and the 2020 National Electrical Code.
The Florida Building Code ties suction outlet protection to ANSI/PHTA/ICC 7, and Charlotte and the City of Naples both ask for drain-cover papers as well. We build the packet off your survey. You sign what needs your signature. We file it.
Collier's application, item by item
Collier's permit type for an in-ground shell is Pool (PRSPL). It asks for engineered structural plans, a dimensioned plan, TDH calculations and the pump details with its curve. You choose the lighting (standard or LED, with or without a niche) and the deck material (wood, concrete or sand-set pavers), and the Residential Swimming Pool Safety Act form records your barrier method.
Watch the site plan. When new impervious area passes 400 sq ft, a Florida surveyor and mapper, architect or engineer has to sign and seal it, and it can't be older than 6 months. On a septic lot it also shows the distance to the system, which must be at least 5 feet under 62-6.005(2) F.A.C.
A stormwater plan, a vegetation removal affidavit on lots of one acre or more, or a preservation review form in the Rural Fringe Mixed Use District may join the pile. The county's application page lists them all. Apply online through the county's GMCD portal or in person at Growth Management.
Screen enclosures, small jobs and the $7,500 letter
A cage isn't part of that application. Collier files it under Aluminum Structure (PRAS), with plans and a site plan per Bulletin 21. If the cage sits over a deck or shell that is permitted separately, you can reuse its certified site plan. You still owe a final spot survey with a note marking the screen-enclosed area. A panel roof adds an index sheet of Florida Product Approval or Miami-Dade NOA numbers. Our screen enclosure wind code guide covers the engineering side.
Starting July 1, 2026, Collier exempts some work valued under $7,500 when you ask in writing and get a letter of exemption. The letter reaches single-family detached homes only, on jobs with no structural, mechanical, electrical, plumbing or gas work, and only outside a flood hazard area. A fence under $7,500 can't count as protection around the water. A new gunite shell has structural and electrical work in it, so the letter doesn't apply.
Collier's ordinance Sec. 22-26 also exempts swapping or repairing pool equipment, other than a heater, on a detached single-family home.
City of Naples: fees, elevations and the temporary fence
Pool permits in Naples city limits run through the Building Department, which takes every application electronically through its public portal. The 2026 residential checklist lists $0.47 per gross square foot with a $100 minimum. Electrical, plumbing and mechanical work adds $0.15 per sq ft with a $125 minimum. Then come a $75 plan review per trade, a $0.01 per sq ft surcharge, an electronic surcharge of 6 percent of the permit fee and $60 for each initial required inspection. Fee schedules change, so confirm these posted numbers with the desk.
Design rules come with it. A pool and deck over 1,000 sq ft needs an inspected temporary construction fence before issue. Outside the main building envelope, the pool and deck can't rise more than 30 inches above the crown of the road, except as noted in Code Sec. 56-45 (the R1-15A district allows 36 inches). After the slab goes down, work stops until the city approves an Elevation Certificate and a Spot Survey.
The city permits the cage and any fence apart from the shell. West of the Coastal Construction Control Line, the job may need prior approval from FDEP and the city's Natural Resource Manager, and the checklist lists October 1 to May 15 as bald eagle nesting season.
Marco Island, Everglades City and Bonita Springs
On Marco Island, Building Services takes applications through the Civic Access Portal. Screen enclosures and fences used as pool barriers need a permit and an inspection there, and the city points owners to the CPSC Safety Barrier Guidelines for Home Pools (Publication 362). It also says you must record a Notice of Commencement with the Clerk of the Circuit Court before work begins on most construction. Our Marco Island page covers the island's builds.
Everglades City contracts with Collier County for building inspections and services, so county staff handle its pool and cage filings. It keeps its own floodplain ordinance and land development code, so read both.
Inside Bonita Springs city limits, skip Lee County and go to the city's Building Division. Ask for its checklist before the drawings are done.
Lee's guide and its inspection codes
Unincorporated Lee County requires a Residential Pool permit for any in-ground shell and for above-ground pools holding water 24 inches deep or more. Contractors file in eConnect; only owner-builders can submit paper. An in-ground shell needs a plot plan, a cross section and plan view, and signed and sealed engineered plans with hydraulic calculations. Suction outlets are identified to ANSI/ASME A112.19.8.
Lee wants every pool enclosed by a fence, wall, screen enclosure or other structure. That takes its own enclosure or fence permit, and the barrier has to be in place at final inspection. An issued permit that doesn't pass at least one inspection within 180 days of issuance expires.
For a below-ground pool, Lee's guide lists 101 Foundation/Footing, 108 Steel with 304 Bonding (requested together), 109 Deck with 304 Bonding, and 119 Final. Renovations and above-ground pools get only the 119 final. Lee also asks for a vegetation removal permit on property over 5 acres (2 acres on Pine Island) or on any barrier island, and a No-Rise certification for land-disturbing work in a regulatory floodway. Historic districts follow the county's historic rules.
Estero, Fort Myers and Cape Coral
Estero's brochure, updated February 21, 2025, lists in-ground and above-ground pools, spas and screen enclosures as permit jobs. In-ground refinishing is a no on the residential side. Floodplain development needs approval, so call before you start.
Fort Myers asks for signed and sealed plans on every site-built pool, plus an entrapment device listing, a boundary survey and a site plan with drainage arrows. Glass within 60 inches of the water's edge and walking surface must be tempered. Fences, pool enclosures, gas lines, and gas or electrical appliances not shown on the pool drawings get separate permits. More than 500 sq ft of added impervious area triggers a Stormwater User Fee Adjustment form, and the Forum and Pelican Preserve need a Design Review Committee letter.
Cape Coral applies through its CSS portal. It always asks for a site plan, layout, engineering, manufacturer specifications, an Electrical Subcontractor Form and a Burrowing Owl/Gopher Tortoise Affidavit. Planned subdivisions skip the Impervious Surface Calculation Worksheet. Inspections cover steel and bonding, deck, bond and pressure, the aluminum structure or fence, a final survey for drainage and an electric final.
Charlotte County and Punta Gorda
Charlotte's pool or spa permit covers spas, swim spas and above-ground pools 24 inches deep or more. The file needs an application, an Affidavit for Accessory Structures, drawings and a site plan with setbacks. In-ground jobs add TDH calculations and ANSI/APSP-7 drain-cover papers. Coastal A and V flood zones need signed and sealed engineering. Reviewers check wind and flood loads under the 8th Edition (2023) Florida Building Code, with no local amendments.
The county posts a $200 flat building fee for an in-ground shell, a surcharge at application, and a $22 zoning review and $90 right-of-way review at issuance. An owner-builder permit bars selling, leasing or renting the property for one year.
Punta Gorda runs its own office. Its fee schedule lists $200 for a swimming pool and $200 for an aluminum cage, and it charges four times the fee when work starts without a permit. Building applications aren't taken online there.
Florida's pool safety law and the barrier rules
Pool permits in Naples are checked against Chapter 515 of the Florida Statutes, the statewide floor for a new residential pool (515.37 exempts a local government whose own pool safety ordinance is equal or stricter). To pass final inspection and earn a certificate of completion, the pool needs at least one of five safety features under F.S. 515.27: a barrier that meets 515.29, an approved safety cover, exit alarms on doors and windows from the house (85 dB A at 10 feet), self-closing and self-latching doors with the release no lower than 54 inches, or a pool alarm certified to ASTM F2208. Local building codes can run stricter, and Lee says every pool needs an enclosure.
A barrier stands at least 4 feet high on the outside and leaves no gap a young child could crawl under, squeeze through or climb. FBC-Residential R4501.17 caps the gap underneath at 2 inches and the openings at a 4-inch sphere, and gates must open outward and self-close and self-latch. A screen enclosure that meets the section can be part or all of the barrier. A dwelling wall counts too, as long as it has no door or window to the pool, or those openings carry an alarm or self-latching option.
Final electrical and barrier inspections come before the water goes in, except on vinyl liner and fiberglass pools. That's a summary, not legal advice. Your permit office decides what applies at your address.
Notice of Commencement: record over $2,500, copy at $5,000
Under F.S. 713.13, the owner records a Notice of Commencement with the clerk before work starts on improvements, unless the job is $2,500 or less (713.02(5)). A new shell clears that line easily. The $5,000 figure is a different rule: F.S. 713.135(1)(e) tells the permit office to get a copy of the recorded notice before the first inspection once the direct contract passes $5,000.
The notice names the property, the work, the owner, the contractor, any surety, any lender and a person designated to receive notices. Local forms vary. Charlotte and Fort Myers want the copy before the first inspection on jobs over $5,000. Lee won't issue the permit on a job over $5,000 until it's recorded. Marco Island says record it before work begins. An older City of Naples form cites the $2,500 line.
Record it before the first dig, not after. We prepare the form, you sign it, and it goes to the Clerk of Court. Lee's guide warns that a missing notice commonly holds up issuance, and a pool permit in Naples or Charlotte stalls at the first inspection without that copy on file.
Flood zones, the coastal line and the 50 percent rule
Flood zones reach the paperwork for a pool permit in Naples, Collier County or Lee County: the city wants an Elevation Certificate after the slab, and Lee's mastered pool plans must name the flood zones they can be permitted in. FEMA's data shows Zone AE with base flood elevations of 8 to 9 feet at several points around Naples. Your lot can differ, so pull your address on the FEMA flood map before you design anything.
Collier's floodplain section asks for an affidavit packet and a cost estimate worksheet when the scope includes reconstruction, rehabilitation, addition or other improvement to a structure. Staff use them to test the job against FEMA's 50 percent improvement rule (44 CFR 59.1). Ask the floodplain desk whether your scope triggers that review. Lee requires a signed and sealed No-Rise certification for land-disturbing work in a regulatory floodway, and Charlotte requires sealed engineering in Coastal A and V zones.
Gulf-front lots bring in the state. The FDEP Coastal Construction Control Line program covers structures that can cause beach erosion or dune damage. Under F.S. 161.053, pools tied to single-family homes that do not advance the line of existing construction and meet siting and design rules can qualify for a general permit, as can resurfacing and minor repairs, with written notice to the department at least 30 days before work. Collier (Rule 62B-34.160) and Lee (Rule 62B-34.150) each have county-specific lines. Ask FDEP and your city or county which approval comes first.
Inspection order, from steel to final
Call Sunshine 811 at least 2 full business days before anyone digs. The notice is free and holds for 30 calendar days (F.S. 556.105). After that, the inspector's calendar runs the job, and pool permits in Naples stay open until the final passes. Lee lists a footing inspection, then steel and bonding, then deck and bonding, then the final. Cape Coral lists steel and bonding, then deck, bond and pressure, then the cage or fence, a drainage survey and the electric final. Naples adds its Elevation Certificate and Spot Survey after the slab.
Groundwater changes the drawings. FBC-Residential R4501.21.4 requires an approved hydrostatic relief device in areas of anticipated water table. In sandy flatwoods soil such as Immokalee fine sand, the NRCS puts the seasonal high water table within 6 to 18 inches of the surface for 1 to 4 months in most years. So the drawings show how the shell handles water pressure when the ground is wet.
The cage adds inspections of its own, and the barrier and electrical finals come before filling. For the money side, see our pool cost guide.
Before the filing: HOA approval and owner-builder work
Your association gets its own say, and a pool permit in Naples, Collier County or Lee County doesn't replace it. The City of Naples application tells you to check deed restrictions with your property owners association. Fort Myers requires a Design Review Committee letter in the Forum and Pelican Preserve. F.S. 720.3035 limits an HOA's architectural review to what its declaration or published guidelines state, requires reasonable and equitable enforcement, and bars the association from restricting your right to choose among the options its documents give for materials, size, design or location. Ask for the guidelines early.
Florida lets owners act as their own contractor on a one- or two-family home for their own use if they supervise the work onsite themselves (F.S. 489.103(7)(a)1). Collier signs owner-builder applications in person with a notary on staff. Selling or leasing within a year of completion creates a presumption the work was for sale or lease. On that route, supervision and inspections are yours.
Send us the address and we file the packet
Need pool permits in Naples, Collier County, Lee County or Charlotte County? Send us the address and your survey. We confirm the desk, prepare the packet and file it, and your written estimate says what that covers. Call (239) 899-6371 or use the contact page for a free estimate.
A canal edge, a golf community or a Gulf-front parcel can raise questions early on. We'd rather sort those out before the drawings are final. Bring the survey, your HOA guidelines if you have them, and any elevation certificate.
Planning a rebuild instead of a new shell? Read about renovation and resurfacing, or see what the cage and deck add.
Sources
- Pool (PRSPL) Application Requirements, Collier County Growth Management
- Aluminum Structures (PRAS), Collier County Growth Management
- Pool/Spa (Private) permit checklist, Residential Pool 2026.10.01, City of Naples Building Department
- Pool (Residential and Commercial) Application and Permitting Guide, Lee County Community Development
- Building Services, City of Marco Island
- Do I Need a Permit brochure, Village of Estero
- Pool (In-Ground) permit guideline, City of Cape Coral Development Services
- Pool/Spa/Fountain checklist, City of Fort Myers Community Development
- Residential Pool or Spa, Charlotte County Community Development
- F.S. Chapter 515, Residential Swimming Pool Safety Act, Florida Legislature
- F.S. 713.135 Notice of commencement and applicability of lien, Florida Legislature
- Coastal Construction Control Line Program, Florida Department of Environmental Protection
- National Flood Hazard Layer, FEMA
- 2023 FBC-Residential, Section R4501.17, UpCodes / ICC Florida Building Code
- Certain qualifying work under $7,500 exempt from building permits, Collier County Building Division
- Everglades City Building Department, City of Everglades City
- Building Codes, Charlotte County Community Development